[{"data":1,"prerenderedAt":15},["ShallowReactive",2],{"page:\u002Felink-fixtures\u002Fdemo":3},{"path":4,"layout":5,"source":6,"title":7,"header":8,"bodyClass":9,"description":10,"ogImage":11,"pageClass":12,"cssFile":13,"html":14},"\u002Felink-fixtures\u002Fdemo","theme","public\u002F_mock\u002Ffixtures\u002Felink-demo.html","How the eLink™ operator GUI works | Boulder Engineering Studio","full","page","A step-by-step walkthrough of the eLink™ operator GUI, from starting a test cycle to reading the result record, with a live demo you can run in your browser.","\u002Fimages\u002Felink-fixtures\u002Fframe-01-gen-2-open-social.jpg","bes-page-elink-fixtures-demo","pages\u002Ffixtures.css","\u003Cdiv class=\"bes-base bes-fx bes-fx--demo\">\n  \u003Csection class=\"dm-hero\">\n    \u003Cdiv class=\"hm-wrap\">\n      \u003Cp class=\"dm-crumb\">\u003Ca href=\"\u002Felink-fixtures\">eLink™ fixtures\u003C\u002Fa> \u002F How the software works\u003C\u002Fp>\n      \u003Ch1>How the eLink™ operator GUI works\u003C\u002Fh1>\n      \u003Cp>Six steps, from opening the fixture to reading the record it keeps for every unit. Every\n        screen below is from the live demo, which you can run yourself further down the page.\u003C\u002Fp>\n    \u003C\u002Fdiv>\n  \u003C\u002Fsection>\n\n  \u003Csection class=\"hm-section hm-section--light\">\n    \u003Cdiv class=\"hm-wrap dm-tour\">\n      \u003Cdiv class=\"dm-steps\" role=\"tablist\" aria-label=\"Walkthrough steps\">\u003Cbutton type=\"button\"\n        role=\"tab\" data-i=\"0\" aria-selected=\"true\">\u003Cp>\u003Cb>Open the fixture\u003C\u002Fb>\u003Cspan>The demo opens\n        with demo mode on, so Login needs no user or password. Then pick Test\n        Fixture.\u003C\u002Fspan>\u003C\u002Fp>\u003C\u002Fbutton>\u003Cbutton type=\"button\" role=\"tab\" data-i=\"1\"\n        aria-selected=\"false\">\u003Cp>\u003Cb>Set up the cycle\u003C\u002Fb>\u003Cspan>The Operate screen has one column for\n        each DUT bay and one row for each step in the test sequence.\u003C\u002Fspan>\u003C\u002Fp>\u003C\u002Fbutton>\u003Cbutton\n        type=\"button\" role=\"tab\" data-i=\"2\" aria-selected=\"false\">\u003Cp>\u003Cb>Run the test\u003C\u002Fb>\u003Cspan>Press\n        Start. Each step runs across every bay at once, and each cell shows its result as it\n        lands.\u003C\u002Fspan>\u003C\u002Fp>\u003C\u002Fbutton>\u003Cbutton type=\"button\" role=\"tab\" data-i=\"3\"\n        aria-selected=\"false\">\u003Cp>\u003Cb>Choose a flow and limits\u003C\u002Fb>\u003Cspan>A flow sets which steps run,\n        in what order. Parameters hold the limits, kept apart from the\n        flow.\u003C\u002Fspan>\u003C\u002Fp>\u003C\u002Fbutton>\u003Cbutton type=\"button\" role=\"tab\" data-i=\"4\"\n        aria-selected=\"false\">\u003Cp>\u003Cb>Read the record\u003C\u002Fb>\u003Cspan>Every cycle is stored with the result\n        and measured value of every step, for every DUT.\u003C\u002Fspan>\u003C\u002Fp>\u003C\u002Fbutton>\u003Cbutton type=\"button\"\n        role=\"tab\" data-i=\"5\" aria-selected=\"false\">\u003Cp>\u003Cb>Follow the log\u003C\u002Fb>\u003Cspan>The log shows\n        every command sent and every reading returned, tagged by DUT.\u003C\u002Fspan>\u003C\u002Fp>\u003C\u002Fbutton>\u003C\u002Fdiv>\n      \u003Cdiv class=\"dm-stage\" role=\"tabpanel\" aria-live=\"polite\">\n        \u003Cdiv class=\"dm-shot\">\u003Cimg src=\"\u002Fimages\u002Ffixtures\u002Fdemo\u002F0-select.webp\"\n          alt=\"The eLink start screen, listing Test Fixture as running.\">\u003Cspan class=\"dm-pin\"\n          aria-hidden=\"true\" style=\"left:50%;top:48%\">1\u003C\u002Fspan>\u003Cspan class=\"dm-pin\"\n          aria-hidden=\"true\" style=\"left:55.5%;top:62.5%\">2\u003C\u002Fspan>\u003C\u002Fdiv>\n        \u003Col class=\"dm-notes\">\u003Cli>\u003Ci>1\u003C\u002Fi>Test Fixture is the test runner software, shown here as\n          running.\u003C\u002Fli>\u003Cli>\u003Ci>2\u003C\u002Fi>Other software installed on the fixture is listed here.\u003C\u002Fli>\u003C\u002Fol>\n        \u003Cdiv class=\"dm-nav\">\n          \u003Cbutton type=\"button\" class=\"prev\" disabled=\"\">\u003Csvg class=\"hm-icon\">\u003Cuse\n            href=\"\u002Fimages\u002Ffixtures\u002Ficons.svg#arrow\">\u003C\u002Fuse>\u003C\u002Fsvg>Back\u003C\u002Fbutton>\n          \u003Csmall>Step 1 of 6\u003C\u002Fsmall>\n          \u003Cbutton type=\"button\" class=\"next\">Next\u003Csvg class=\"hm-icon\">\u003Cuse\n            href=\"\u002Fimages\u002Ffixtures\u002Ficons.svg#arrow\">\u003C\u002Fuse>\u003C\u002Fsvg>\u003C\u002Fbutton>\n        \u003C\u002Fdiv>\n      \u003C\u002Fdiv>\n    \u003C\u002Fdiv>\n  \u003C\u002Fsection>\n\n  \u003Csection class=\"hm-section hm-section--dark dm-live\" id=\"live\">\n    \u003Cdiv class=\"hm-wrap\">\n      \u003Cdiv class=\"hm-section-head\" style=\"text-align:center\">\n        \u003Ch2 class=\"hm-h2\">Try it yourself\u003C\u002Fh2>\n        \u003Cp class=\"hm-lede\" style=\"margin:0 auto\">Press Login (no user or password), open Test\n          Fixture, and press Start.\u003C\u002Fp>\n      \u003C\u002Fdiv>\n      \u003Cdiv class=\"fx-device\">\n        \u003Cdiv class=\"fx-device__bar\">\u003Ci>\u003C\u002Fi>\u003Ci>\u003C\u002Fi>\u003Ci>\u003C\u002Fi>\u003Cspan>elink.boulderes.com\u003C\u002Fspan>\u003Ca\n          href=\"https:\u002F\u002Felink.boulderes.com\u002F\" target=\"_blank\" rel=\"noopener\">Open in new\n          tab\u003C\u002Fa>\u003C\u002Fdiv>\n        \u003Cdiv class=\"fx-frame\">\n          \u003Cbutton type=\"button\" class=\"fx-frame__poster\"\n            style=\"background-image:url(\u002Fimages\u002Ffixtures\u002Fdemo\u002F0-select.webp)\"\n            aria-label=\"Load the live eLink demo\">\u003Cspan>\u003Csvg class=\"hm-icon\">\u003Cuse\n            href=\"\u002Fimages\u002Ffixtures\u002Ficons.svg#arrow\">\u003C\u002Fuse>\u003C\u002Fsvg>Load the live demo\u003C\u002Fspan>\u003C\u002Fbutton>\n        \u003C\u002Fdiv>\n      \u003C\u002Fdiv>\n    \u003C\u002Fdiv>\n  \u003C\u002Fsection>\n\n  \u003Csection class=\"hm-section hm-section--light\">\n    \u003Cdiv class=\"hm-wrap\">\n      \u003Cdiv class=\"hm-section-head\">\u003Ch2 class=\"hm-h2\">What the demo does not show\u003C\u002Fh2>\u003C\u002Fdiv>\n      \u003Cdiv class=\"dm-limits\">\n        \u003Cdiv>\u003Ch3>Simulated hardware\u003C\u002Fh3>\u003Cp>The demo runs without a fixture attached, so its\n          measurements are generated. It shows how a cycle runs and what gets recorded, not how a\n          particular test performs.\u003C\u002Fp>\u003C\u002Fdiv>\n        \u003Cdiv>\u003Ch3>An example sequence\u003C\u002Fh3>\u003Cp>The demo's power, rail, firmware, and RF steps are an\n          example. Your fixture runs the procedures written for your DUT, and RF testing is\n          design-package work.\u003C\u002Fp>\u003C\u002Fdiv>\n        \u003Cdiv>\u003Ch3>Your fixture, configured\u003C\u002Fh3>\u003Cp>On a delivered fixture, the screens, flows, and\n          limits are set up for your product and your line.\u003C\u002Fp>\u003C\u002Fdiv>\n      \u003C\u002Fdiv>\n      \u003Cdiv class=\"hm-cta\" style=\"margin-top:44px\">\n        \u003Cdiv>\u003Ch2 style=\"font-size:24px\">Want to see it on your DUT?\u003C\u002Fh2>\u003Cp\n          style=\"color:var(--bes-muted)\">Tell us what your board needs to be tested for.\u003C\u002Fp>\u003C\u002Fdiv>\n        \u003Ca class=\"hm-btn hm-btn--primary\"\n          href=\"\u002Fconnect?looking_for=eLink%E2%84%A2%20test%20fixture\">Talk with a fixture\n          engineer\u003C\u002Fa>\n      \u003C\u002Fdiv>\n    \u003C\u002Fdiv>\n  \u003C\u002Fsection>\n\u003Cscript type=\"application\u002Fjson\" class=\"dm-data\">[{\"t\": \"Open the fixture\", \"s\": \"The demo opens with demo mode on, so Login needs no user or password. Then pick Test Fixture.\", \"img\": \"\u002Fimages\u002Ffixtures\u002Fdemo\u002F0-select.webp\", \"alt\": \"The eLink start screen, listing Test Fixture as running.\", \"pins\": [[50, 48, \"Test Fixture is the test runner software, shown here as running.\"], [55.5, 62.5, \"Other software installed on the fixture is listed here.\"]]}, {\"t\": \"Set up the cycle\", \"s\": \"The Operate screen has one column for each DUT bay and one row for each step in the test sequence.\", \"img\": \"\u002Fimages\u002Ffixtures\u002Fdemo\u002F1-operate.webp\", \"alt\": \"The Operate screen before a cycle, with four empty bays.\", \"pins\": [[66, 24, \"One column per DUT bay. This demo fixture has four.\"], [17, 60, \"The test sequence: power on, measure the 3V3 rail, program firmware, and an RF suite.\"], [22, 12.5, \"Demo switches: auto-run, number of DUTs, continue after a failure, barcode scanning.\"], [91, 77, \"Start runs the cycle. Stop and Reset sit above it.\"]]}, {\"t\": \"Run the test\", \"s\": \"Press Start. Each step runs across every bay at once, and each cell shows its result as it lands.\", \"img\": \"\u002Fimages\u002Ffixtures\u002Fdemo\u002F2-running.webp\", \"alt\": \"A cycle in progress: two bays failed at power on, two passed and are programming firmware.\", \"pins\": [[34, 44, \"Bays 1 and 2 failed at power on, so they stop there.\"], [66, 61, \"Passing steps show the measured value: 3.36 V and 3.29 V on the 3V3 rail.\"], [66, 76, \"Blue cells are running. The other bays carry on without waiting.\"], [66, 30, \"The top row is the overall pass or fail for each DUT.\"]]}, {\"t\": \"Choose a flow and limits\", \"s\": \"A flow sets which steps run, in what order. Parameters hold the limits, kept apart from the flow.\", \"img\": \"\u002Fimages\u002Ffixtures\u002Fdemo\u002F3-configure.webp\", \"alt\": \"The Configure screen with two flows, two parameter sets, and their YAML.\", \"pins\": [[19, 14, \"Flows: fully automatic, or with an operator visual check at the end.\"], [19, 38, \"Parameter sets: nominal or tight limits for the same flow.\"], [77, 72, \"Both are plain YAML, so a technician can read and change them.\"]]}, {\"t\": \"Read the record\", \"s\": \"Every cycle is stored with the result and measured value of every step, for every DUT.\", \"img\": \"\u002Fimages\u002Ffixtures\u002Fdemo\u002F4-results.webp\", \"alt\": \"The Results screen showing one cycle: values for each DUT, with one power-on failure and one RF failure.\", \"pins\": [[18, 26, \"Every cycle, newest first.\"], [64, 45, \"Measured values per DUT: rail voltage, firmware version, RF signal strength.\"], [43, 4, \"Run metadata and the runner log sit beside the results.\"], [96.5, 4, \"Download the cycle record.\"]]}, {\"t\": \"Follow the log\", \"s\": \"The log shows every command sent and every reading returned, tagged by DUT.\", \"img\": \"\u002Fimages\u002Ffixtures\u002Fdemo\u002F5-log.webp\", \"alt\": \"The runner log, with commands, readings, and two failures in red.\", \"pins\": [[27, 4.5, \"Filter by DUT or by level.\"], [48, 54.5, \"Failures in red, with the reading that caused them: an overcurrent trip at 705 mA.\"], [52, 75, \"Readings are logged with their limits: 3V3 rail 3.33 V, limits 3.20 V to 3.40 V.\"]]}]\u003C\u002Fscript>\n\u003C\u002Fdiv>",1795194793176]