[{"data":1,"prerenderedAt":15},["ShallowReactive",2],{"page:\u002Felink-fixtures":3},{"path":4,"layout":5,"source":6,"title":7,"header":8,"bodyClass":9,"description":10,"ogImage":11,"pageClass":12,"cssFile":13,"html":14},"\u002Felink-fixtures","theme","site-pages\u002Fother\u002Fprogramming-test-fixtures.html","eLink™ programming and test fixtures | Boulder Engineering Studio","full","page","eLink™ flip-top fixtures for firmware programming and functional test of PCBAs and finished devices, with a software development framework, operator GUI, and a logged result for each unit.","\u002Fimages\u002Felink-fixtures\u002Fframe-01-gen-2-open-social.jpg","bes-page-elink-fixtures","pages\u002Ffixtures.css","\u003Cdiv class=\"bes-base bes-fx\">\n  \n  \u003Csection class=\"fx-hero\">\n    \u003Cdiv class=\"hm-wrap\">\n      \u003Cdiv class=\"fx-hero__main\">\n        \u003Cdiv>\n          \u003Cp class=\"hm-eyebrow\">Programming and test fixtures\u003C\u002Fp>\n          \u003Ch1>eLink™ fixtures, from engineering bench to production line\u003C\u002Fh1>\n          \u003Cp class=\"fx-hero__lead\">A flip-top fixture platform for programming and testing PCBAs and\n            finished devices, used in aerospace, medical, undersea, automotive, industrial, and\n            manufacturing programs. No per-seat programming license fees.\u003C\u002Fp>\n          \u003Cdiv class=\"hm-btns\">\n            \u003Ca class=\"hm-btn hm-btn--primary\"\n              href=\"\u002Fconnect?looking_for=eLink%E2%84%A2%20test%20fixture\">Talk with a fixture\n              engineer\u003C\u002Fa>\n            \u003Ca class=\"hm-btn hm-btn--ghost\" href=\"\u002Felink-fixtures\u002Fdemo\">See how the software\n              works\u003C\u002Fa>\n          \u003C\u002Fdiv>\n        \u003C\u002Fdiv>\n        \u003Cdiv class=\"fx-hero__img\">\u003Cimg\n          src=\"\u002Fimages\u002Felink-fixtures\u002Fframe-01-gen-2-closed-over-dut.webp\"\n          alt=\"Frame 01 Gen 2 closed over a DUT, with the press handle raised.\">\u003C\u002Fdiv>\n      \u003C\u002Fdiv>\n      \u003Cdiv class=\"fx-boxes\">\n        \u003Cdiv>\u003Csvg>\u003Cuse\n          href=\"\u002Fimages\u002Ffixtures\u002Ficons.svg#fixture\">\u003C\u002Fuse>\u003C\u002Fsvg>\u003Csection>\u003Ch2>Access\u003C\u002Fh2>\u003Cp>Spring-pin\n          access to your test points, from the first prototype board onward, replaces fly wires and\n          the debugging time they cost.\u003C\u002Fp>\u003C\u002Fsection>\u003C\u002Fdiv>\n        \u003Cdiv>\u003Csvg>\u003Cuse href=\"\u002Fimages\u002Ffixtures\u002Ficons.svg#review\">\u003C\u002Fuse>\u003C\u002Fsvg>\u003Csection>\u003Ch2>Detect\n          failures\u003C\u002Fh2>\u003Cp>Program and test each unit the same way, with bench instruments or custom\n          test hardware, and catch failing boards before they ship.\u003C\u002Fp>\u003C\u002Fsection>\u003C\u002Fdiv>\n        \u003Cdiv>\u003Csvg>\u003Cuse\n          href=\"\u002Fimages\u002Ffixtures\u002Ficons.svg#sys\">\u003C\u002Fuse>\u003C\u002Fsvg>\u003Csection>\u003Ch2>Report\u003C\u002Fh2>\u003Cp>Each result\n          is logged and can be sent to your systems. Fixtures take software and configuration\n          updates remotely, so all stations run the same test whether or not you are on the\n          floor.\u003C\u002Fp>\u003C\u002Fsection>\u003C\u002Fdiv>\n      \u003C\u002Fdiv>\n    \u003C\u002Fdiv>\n  \u003C\u002Fsection>\n\n  \n  \u003Csection class=\"hm-section hm-section--light\">\n    \u003Cdiv class=\"hm-wrap\">\n      \u003Cdiv class=\"hm-section-head\">\u003Ch2 class=\"hm-h2\">Who it is for\u003C\u002Fh2>\u003C\u002Fdiv>\n      \u003Cdiv class=\"fx-seg\">\n        \u003Carticle>\u003Csvg>\u003Cuse href=\"\u002Fimages\u002Ffixtures\u002Ficons.svg#elec\">\u003C\u002Fuse>\u003C\u002Fsvg>\u003Cspan\n          class=\"hm-eyebrow\">Design engineers\u003C\u002Fspan>\u003Ch3>Measure the real board\u003C\u002Fh3>\u003Cp>Reliable pin\n          access to as-built hardware replaces the rat's nest of fly wires. Measure actual\n          performance instead of relying on simulation.\u003C\u002Fp>\u003C\u002Farticle>\n        \u003Carticle>\u003Csvg>\u003Cuse href=\"\u002Fimages\u002Ffixtures\u002Ficons.svg#ind\">\u003C\u002Fuse>\u003C\u002Fsvg>\u003Cspan\n          class=\"hm-eyebrow\">Contract manufacturers\u003C\u002Fspan>\u003Ch3>Run each unit the same\n          way\u003C\u002Fh3>\u003Cp>Program and test one unit at a time, several in parallel, or a full panel, by\n          changing configuration rather than hardware. Results export to your systems or your\n          customer's, with no per-seat license cost at each station.\u003C\u002Fp>\u003C\u002Farticle>\n        \u003Carticle>\u003Csvg>\u003Cuse href=\"\u002Fimages\u002Ffixtures\u002Ficons.svg#sw\">\u003C\u002Fuse>\u003C\u002Fsvg>\u003Cspan\n          class=\"hm-eyebrow\">Firmware developers\u003C\u002Fspan>\u003Ch3>Debug on real hardware\u003C\u002Fh3>\u003Cp>Reach any\n          module on the as-built design instead of a cobbled-together development kit, and triage\n          real issues as they happen.\u003C\u002Fp>\u003C\u002Farticle>\n        \u003Carticle>\u003Csvg>\u003Cuse href=\"\u002Fimages\u002Ffixtures\u002Ficons.svg#check\">\u003C\u002Fuse>\u003C\u002Fsvg>\u003Cspan\n          class=\"hm-eyebrow\">Quality control\u003C\u002Fspan>\u003Ch3>A record for each unit\u003C\u002Fh3>\u003Cp>Track passes,\n          log failures with their measured values, and quarantine failing units. The same record\n          follows the product through NPI, production, and returns.\u003C\u002Fp>\u003C\u002Farticle>\n      \u003C\u002Fdiv>\n      \u003Cp style=\"margin-top:28px\">\u003Ca class=\"hm-btn hm-btn--primary\"\n        href=\"\u002Fconnect?looking_for=eLink%E2%84%A2%20test%20fixture\">Talk with a fixture\n        engineer\u003C\u002Fa>\u003C\u002Fp>\n    \u003C\u002Fdiv>\n  \u003C\u002Fsection>\n\n  \n  \u003Csection class=\"hm-section\">\n    \u003Cdiv class=\"hm-wrap\">\n      \u003Cdiv class=\"fx-plat\">\n        \u003Cdiv>\n          \u003Ch2 class=\"hm-h2\">What makes an eLink fixture\u003C\u002Fh2>\n          \u003Cp>eLink is sold as three parts: Frame 01 Gen 2 (BT201), the flip-top press; the eLink\n            Test Runner SDK, a software development framework and operator GUI; and configuration\n            and customization services that adapt both to your product. Buy the base frame and build\n            on it yourself, have us integrate hardware you already have, or have us design the whole\n            fixture.\u003C\u002Fp>\n          \u003Cp>Inside the frame, a fixture has three working elements: the DUT interface, the control\n            board, and the test runner. The base frame ships without requiring customization. DUT interface\n            and pogo design, control board design, and software and GUI customization are added as a\n            design package, sized to what your product needs.\u003C\u002Fp>\n        \u003C\u002Fdiv>\n        \u003Cdiv class=\"fx-parts\" aria-label=\"The three parts of eLink\">\n          \u003Cdiv class=\"tx-hex-lt\">\u003Cspan class=\"n\">\u003Csvg>\u003Cuse\n            href=\"\u002Fimages\u002Ffixtures\u002Ficons.svg#fixture\">\u003C\u002Fuse>\u003C\u002Fsvg>\u003C\u002Fspan>\u003Cp>\u003Cb>Frame 01 Gen 2\n            (BT201)\u003C\u002Fb>\u003Cspan>The flip-top press. Sold on its own as the base frame.\u003C\u002Fspan>\u003C\u002Fp>\u003C\u002Fdiv>\n          \u003Cdiv class=\"tx-code-lt\">\u003Cspan class=\"n\">\u003Csvg>\u003Cuse\n            href=\"\u002Fimages\u002Ffixtures\u002Ficons.svg#sw\">\u003C\u002Fuse>\u003C\u002Fsvg>\u003C\u002Fspan>\u003Cp>\u003Cb>eLink Test Runner SDK\u003C\u002Fb>\u003Cspan>A software development framework and operator GUI.\u003C\u002Fspan>\u003C\u002Fp>\u003C\u002Fdiv>\n          \u003Cdiv class=\"is-pkg\">\u003Cspan class=\"n\">\u003Csvg>\u003Cuse\n            href=\"\u002Fimages\u002Ffixtures\u002Ficons.svg#wrench\">\u003C\u002Fuse>\u003C\u002Fsvg>\u003C\u002Fspan>\u003Cp>\u003Cb>Configuration and\n            customization services\u003C\u002Fb>\u003Cspan>Design package: DUT interface and pogo design, control\n            board design, software and GUI customization.\u003C\u002Fspan>\u003C\u002Fp>\u003C\u002Fdiv>\n        \u003C\u002Fdiv>\n      \u003C\u002Fdiv>\n      \u003Col class=\"fx-steps\" aria-label=\"How a custom fixture is built\">\n        \u003Cli>DUT and test requirements\u003C\u002Fli>\n        \u003Cli>Test runner architecture and hardware development\u003C\u002Fli>\n        \u003Cli>Fabrication and test\u003C\u002Fli>\n        \u003Cli>Validation and commissioning\u003C\u002Fli>\n        \u003Cli>Deployment\u003C\u002Fli>\n      \u003C\u002Fol>\n    \u003C\u002Fdiv>\n  \u003C\u002Fsection>\n\n  \n  \u003Csection class=\"hm-section hm-section--light\">\n    \u003Cdiv class=\"hm-wrap\">\n      \u003Cdiv class=\"fx-el\">\n        \u003Cfigure>\u003Cimg src=\"\u002Fimages\u002Felink-fixtures\u002Fpogo-pins-fixture-plate.webp\"\n          alt=\"Pogo pins in a fixture plate, seen from the side.\">\u003C\u002Ffigure>\n        \u003Cdiv>\n          \u003Cp class=\"hm-eyebrow\">\u003Csvg>\u003Cuse href=\"\u002Fimages\u002Ffixtures\u002Ficons.svg#fixture\">\u003C\u002Fuse>\u003C\u002Fsvg>DUT\n            interface\u003C\u002Fp>\n          \u003Ch2>Reach all the test points on your DUT.\u003C\u002Fh2>\n          \u003Ch3>How we build it\u003C\u002Fh3>\n          \u003Cp>Pogo plate assemblies give repeatable contact with dense test points. Machined nests\n            hold the DUT in place during test and release it quickly before and after. The pogo\n            plate mounts on a 50 mm grid with 46 threaded positions, inside a DUT area of 230 × 140\n            × 35 mm.\u003C\u002Fp>\n          \u003Ch3>What to expect\u003C\u002Fh3>\n          \u003Cul class=\"fx-expect\">\n            \u003Cli>\u003Cb>Direct-soldered pins.\u003C\u002Fb>No wire-wrap and no crimped connections, and ribbon\n              cables in place of loose signal wires.\u003C\u002Fli>\n            \u003Cli>\u003Cb>Fast to deploy.\u003C\u002Fb>Custom fixtures in as few as 4–8 weeks.\u003C\u002Fli>\n            \u003Cli>\u003Cb>Open underneath.\u003C\u002Fb>The hinged chassis opens without tools for board debug and\n              component swaps.\u003C\u002Fli>\n            \u003Cli>\u003Cb>Modular.\u003C\u002Fb>Spring pins and nests are replaceable, so a worn part is a short\n              repair rather than a new fixture.\u003C\u002Fli>\n          \u003C\u002Ful>\n        \u003C\u002Fdiv>\n      \u003C\u002Fdiv>\n\n      \u003Cdiv class=\"fx-el is-flip\">\n        \u003Cfigure>\u003Cimg src=\"\u002Fimages\u002Felink-fixtures\u002Ffixture-control-board.webp\"\n          alt=\"A fixture control board installed in the frame, with a grounding lead.\">\u003C\u002Ffigure>\n        \u003Cdiv>\n          \u003Cp class=\"hm-eyebrow\">\u003Csvg>\u003Cuse href=\"\u002Fimages\u002Ffixtures\u002Ficons.svg#elec\">\u003C\u002Fuse>\u003C\u002Fsvg>Control\n            interface\u003C\u002Fp>\n          \u003Ch2>Power, test, and communicate with your DUT.\u003C\u002Fh2>\n          \u003Ch3>How we build it\u003C\u002Fh3>\n          \u003Cp>A control board, designed for your product as part of the design package, powers the\n            DUT, talks to it, and runs the measurements. It also connects the peripherals your line\n            uses, such as screens, programmers, and barcode scanners. Short cable and trace runs\n            between the board and the DUT keep signals clean.\u003C\u002Fp>\n          \u003Ch3>What to expect\u003C\u002Fh3>\n          \u003Cul class=\"fx-expect\">\n            \u003Cli>\u003Cb>Built for your test.\u003C\u002Fb>Proven design blocks are combined into a board for your\n              DUT.\u003C\u002Fli>\n            \u003Cli>\u003Cb>Fewer cables.\u003C\u002Fb>Onboard circuitry shortens cable runs and reduces programming\n              errors.\u003C\u002Fli>\n            \u003Cli>\u003Cb>Documented.\u003C\u002Fb>Each board is drawn from our layout library and delivered with\n              documentation.\u003C\u002Fli>\n            \u003Cli>\u003Cb>Easy to connect.\u003C\u002Fb>Configurable headers make setup and access quick.\u003C\u002Fli>\n          \u003C\u002Ful>\n        \u003C\u002Fdiv>\n      \u003C\u002Fdiv>\n\n      \u003Cdiv class=\"fx-el\">\n        \u003Cfigure class=\"is-screen\">\n          \u003Cimg src=\"\u002Fimages\u002Ffixtures\u002Fdemo\u002F2-running.webp\"\n            alt=\"The eLink operator screen, showing four test bays, the test sequence, and start, stop, and reset buttons.\">\n          \u003Cfigcaption>Operator screen from the live demo, mid-cycle.\u003Ca class=\"hm-more\"\n            href=\"\u002Felink-fixtures\u002Fdemo\">How it works \u003Csvg class=\"hm-icon\">\u003Cuse\n            href=\"\u002Fimages\u002Ffixtures\u002Ficons.svg#arrow\">\u003C\u002Fuse>\u003C\u002Fsvg>\u003C\u002Fa>\u003C\u002Ffigcaption>\n        \u003C\u002Ffigure>\n        \u003Cdiv>\n          \u003Cp class=\"hm-eyebrow\">\u003Csvg>\u003Cuse href=\"\u002Fimages\u002Ffixtures\u002Ficons.svg#sw\">\u003C\u002Fuse>\u003C\u002Fsvg>Test\n            runner\u003C\u002Fp>\n          \u003Ch2>Pass good units. Catch the failures.\u003C\u002Fh2>\n          \u003Ch3>How we build it\u003C\u002Fh3>\n          \u003Cp>The eLink test runner SDK is a software development framework designed to enable rapid deployment of test fixtures. Your test sequence is a list of\n            procedures, run in parallel across all DUT bays in the fixture, and each procedure\n            returns a pass or fail with the measured values stored alongside it. Signal switching\n            lets several DUTs share measurement circuitry, which holds down hardware cost while\n            keeping tests parallel. The operator GUI walks operators through each cycle.\u003C\u002Fp>\n          \u003Ch3>What to expect\u003C\u002Fh3>\n          \u003Cul class=\"fx-expect\">\n            \u003Cli>\u003Cb>Traceable.\u003C\u002Fb>Results are stored on the fixture and can be exported through a web\n              interface, an API, a USB drive, or to your cloud or on-premises systems.\u003C\u002Fli>\n            \u003Cli>\u003Cb>Containerized.\u003C\u002Fb>Fixture software runs in containers, so one update package goes\n              to one fixture or a whole fleet.\u003C\u002Fli>\n            \u003Cli>\u003Cb>Configurable.\u003C\u002Fb>Limits and settings sit apart from the test sequence, so one\n              fixture can test several board variants, and a technician can change limits without\n              touching the tests.\u003C\u002Fli>\n            \u003Cli>\u003Cb>Simple to operate.\u003C\u002Fb>Operators need no test background to start a cycle and read\n              the result.\u003C\u002Fli>\n          \u003C\u002Ful>\n        \u003C\u002Fdiv>\n      \u003C\u002Fdiv>\n    \u003C\u002Fdiv>\n  \u003C\u002Fsection>\n\n  \n  \u003Csection class=\"hm-section hm-section--dark\" id=\"demo\">\n    \u003Cdiv class=\"hm-wrap fx-demo\">\n      \u003Cdiv>\n        \u003Cp class=\"hm-eyebrow\" style=\"color:var(--bes-yellow)\">Demo\u003C\u002Fp>\n        \u003Ch2 class=\"hm-h2\">Watch a test cycle run\u003C\u002Fh2>\n        \u003Cp class=\"hm-lede\">The eLink operator GUI, running against simulated hardware. An operator\n          starts a cycle on four bays, one unit fails at power-on, and the result record shows the\n          measured values for each unit.\u003C\u002Fp>\n        \u003Cdiv class=\"hm-btns\" style=\"margin-top:26px\">\n          \u003Ca class=\"hm-btn hm-btn--primary\" href=\"\u002Felink-fixtures\u002Fdemo\">Step-by-step walkthrough\u003C\u002Fa>\n          \u003Ca class=\"hm-btn hm-btn--ghost\" href=\"\u002Felink-fixtures\u002Fdemo#live\">Try the live demo\u003C\u002Fa>\n        \u003C\u002Fdiv>\n      \u003C\u002Fdiv>\n      \u003Cdiv class=\"fx-device\">\n        \u003Cdiv class=\"fx-device__bar\">\u003Ci>\u003C\u002Fi>\u003Ci>\u003C\u002Fi>\u003Ci>\u003C\u002Fi>\u003Cspan>eLink operator GUI, recorded from the\n          live demo\u003C\u002Fspan>\u003C\u002Fdiv>\n        \u003Cdiv class=\"fx-frame\">\n          \u003Cvideo class=\"fx-video\" src=\"\u002Fimages\u002Ffixtures\u002Fdemo\u002Felink-demo.webm\"\n            poster=\"\u002Fimages\u002Ffixtures\u002Fdemo\u002Felink-demo-poster.webp\" muted=\"\" loop=\"\" playsinline=\"\"\n            controls=\"\" preload=\"metadata\"\n            aria-label=\"Recording of the eLink operator GUI: logging in, running a test cycle on four bays, and opening the result record\">\u003C\u002Fvideo>\n        \u003C\u002Fdiv>\n      \u003C\u002Fdiv>\n    \u003C\u002Fdiv>\n  \u003C\u002Fsection>\n\n  \n  \u003Csection class=\"hm-section hm-section--light\">\n    \u003Cdiv class=\"hm-wrap\">\n      \u003Cdiv class=\"fx-faq-head\">\n        \u003Ch2 class=\"hm-h2\" style=\"margin:0\">Frequently asked questions\u003C\u002Fh2>\n        \u003Cinput id=\"fx-faq-search\" type=\"search\" placeholder=\"Search the questions\"\n          aria-label=\"Search the questions\">\n      \u003C\u002Fdiv>\n      \u003Cp class=\"fx-faq-empty\">No questions match. \u003Ca\n        href=\"\u002Fconnect?looking_for=eLink%E2%84%A2%20test%20fixture\">Ask us directly.\u003C\u002Fa>\u003C\u002Fp>\n      \u003Cdiv class=\"fx-faq\">\n        \u003Cdetails>\u003Csummary>What DUT features can be tested?\u003C\u002Fsummary>\u003Cdiv class=\"a\">\n          \u003Cp>The list below gives examples, not a complete list. Power, measurement, and programming\n            are part of most fixtures. Most of the items below need instruments or custom hardware\n            added in the design package, and RF protocol testing is always design-package work. Ask\n            us about anything not listed.\u003C\u002Fp>\n          \u003Ch4>Physical elements\u003C\u002Fh4>\u003Cul>\u003Cli>Actuation (toggle switches, rotary switches,\n            sliders)\u003C\u002Fli>\u003Cli>User interface elements on the DUT (screens, buttons,\n            LEDs)\u003C\u002Fli>\u003Cli>Connector interfaces on the DUT (HDMI, DisplayPort, USB, 10\u002F100\u002F1000BASE-T\n            Ethernet, IR, RS-232\u002FRS-422\u002FRS-485 serial, CAN bus, coax, U.FL, and\n            others)\u003C\u002Fli>\u003Cli>Sensors (humidity, temperature, IMU, magnetic, and\n            others)\u003C\u002Fli>\u003Cli>Thermal: heat sink effectiveness, component temperatures\u003C\u002Fli>\u003C\u002Ful>\n          \u003Ch4>RF\n            interfaces\u003C\u002Fh4>\u003Cul>\u003Cli>LTE\u002FCAT-M\u003C\u002Fli>\u003Cli>Bluetooth\u003C\u002Fli>\u003Cli>Wi-Fi\u003C\u002Fli>\u003Cli>GPS\u002FGLONASS\u002FGalileo\u002FBeiDou\u003C\u002Fli>\u003Cli>LoRa\u003C\u002Fli>\u003Cli>Z-Wave\u002FZigbee\u002FXBee\u003C\u002Fli>\u003Cli>NFC\u003C\u002Fli>\u003Cli>Inductive\n            charging and communications\u003C\u002Fli>\u003C\u002Ful>\n          \u003Ch4>Signals\u003C\u002Fh4>\u003Cul>\u003Cli>Voltage and current measurements\u003C\u002Fli>\u003Cli>Power consumption and\n            charge\u002Fdischarge (using power loads)\u003C\u002Fli>\u003Cli>Waveform injection or analysis (using\n            oscilloscopes or logic analyzers integrated as part of the design\n            package)\u003C\u002Fli>\u003Cli>Communication protocols: SPI, I2C, UART, USB, CAN, and\n            others\u003C\u002Fli>\u003Cli>EMI\u003C\u002Fli>\u003C\u002Ful>\n        \u003C\u002Fdiv>\u003C\u002Fdetails>\n        \u003Cdetails>\u003Csummary>What custom features can be added to control boards?\u003C\u002Fsummary>\u003Cdiv\n          class=\"a\">\n          \u003Cp>If you need a feature that is not on this list or in the DUT features answer, ask\n            us.\u003C\u002Fp>\n          \u003Cul>\u003Cli>Impedance-controlled design\u003C\u002Fli>\u003Cli>Inductive load drivers (motors, solenoids, and\n            others)\u003C\u002Fli>\u003Cli>Operator controls (buttons, switches, LEDs, external\n            screen)\u003C\u002Fli>\u003Cli>Operator-accessible connectors (USB, HDMI, power, coax, RJ45, banana\n            plugs, and others)\u003C\u002Fli>\u003Cli>Humidity and temperature sensors\u003C\u002Fli>\u003C\u002Ful>\n        \u003C\u002Fdiv>\u003C\u002Fdetails>\n        \u003Cdetails>\u003Csummary>Are test points required on my DUT?\u003C\u002Fsummary>\u003Cdiv class=\"a\">\n          \u003Cp>Dedicated test pads are preferred, but what matters is access to the signals. Typical\n            access points:\u003C\u002Fp>\n          \u003Cul>\u003Cli>Test pads, free of solder and coating (preferred)\u003C\u002Fli>\u003Cli>Plated through-holes\n            with no component installed (preferred)\u003C\u002Fli>\u003Cli>Other possible access points: headers,\n            connectors, unmasked vias, SMT component pads or leads, through-hole component pads or\n            leads\u003C\u002Fli>\u003C\u002Ful>\n          \u003Cp>Denser or harder-to-reach connections take more development and can be less reliable in\n            production. If your board is still in design, we can review it for testability before\n            layout is final.\u003C\u002Fp>\n        \u003C\u002Fdiv>\u003C\u002Fdetails>\n        \u003Cdetails>\u003Csummary>How does microcontroller programming work?\u003C\u002Fsummary>\u003Cdiv class=\"a\">\n          \u003Cp>eLink fixtures can program several units in parallel (ganged programming), and the\n            method supports most microcontrollers. The driver library includes OpenOCD with FT2232\n            adapters, openFPGALoader for Lattice FPGAs, MSP-FET, and SEGGER J-Link for Nordic parts.\n            Other programmers can be integrated. The right method depends on hardware cost,\n            development effort, firmware size, and the programming speed you need.\u003C\u002Fp>\n        \u003C\u002Fdiv>\u003C\u002Fdetails>\n        \u003Cdetails>\u003Csummary>What accessories are available?\u003C\u002Fsummary>\u003Cdiv class=\"a\">\n          \u003Cp>Standard accessories:\u003C\u002Fp>\n          \u003Cul>\u003Cli>Blank FR4 plates\u003C\u002Fli>\u003Cli>Blank acrylic plates\u003C\u002Fli>\u003Cli>Vanity and security\n            panels\u003C\u002Fli>\u003Cli>Signal fanout boards\u003C\u002Fli>\u003C\u002Ful>\n          \u003Cp>Also available: machined nests, fanout debug and expansion boards, tamper-resistant\n            construction, enhanced chassis grounding, and auxiliary benchtop housings. We also\n            design custom accessories, and the frame works as a base for fixtures you build\n            yourself.\u003C\u002Fp>\n        \u003C\u002Fdiv>\u003C\u002Fdetails>\n        \u003Cdetails>\u003Csummary>What documentation is included?\u003C\u002Fsummary>\u003Cdiv class=\"a\">\n          \u003Cp>The base frame comes with the BT201 datasheet, covering mounting points, overall\n            dimensions, recommended hardware, and recommended accessory configurations.\u003C\u002Fp>\n          \u003Cp>Documentation for a custom fixture depends on what it includes, but typically\n            covers:\u003C\u002Fp>\n          \u003Cul>\u003Cli>Maintenance guides and replacement walkthroughs for wear parts such as\n            pins\u003C\u002Fli>\u003Cli>Operator documentation for the software interface\u003C\u002Fli>\u003Cli>Engineering\n            documentation for the software architecture, for teams customizing or extending their\n            tests\u003C\u002Fli>\u003C\u002Ful>\n        \u003C\u002Fdiv>\u003C\u002Fdetails>\n        \u003Cdetails>\u003Csummary>How many cycles does a fixture last?\u003C\u002Fsummary>\u003Cdiv class=\"a\">\n          \u003Cp>The frame is rated for 2,000,000+ cycles, with a maintenance interval of 250,000\n            cycles. Maintenance is a gas strut replacement, done in the field in under 10\n            minutes.\u003C\u002Fp>\n          \u003Cp>That rating covers the mechanical frame only. Pin life depends on the pins and the\n            configuration, so we quote it per fixture. Pins can typically be replaced or refurbished\n            without taking the fixture apart.\u003C\u002Fp>\n        \u003C\u002Fdiv>\u003C\u002Fdetails>\n        \u003Cdetails>\u003Csummary>Can I update my fixture?\u003C\u002Fsummary>\u003Cdiv class=\"a\">\n          \u003Cp>Yes. Fixture software runs in containers, and the eLink connectivity client handles\n            configuration management, update coordination, and cloud sync across your fixtures.\n            Updates to the operator interface and test software can be pushed with or without an\n            operator at the station.\u003C\u002Fp>\n        \u003C\u002Fdiv>\u003C\u002Fdetails>\n        \u003Cdetails>\u003Csummary>What do I do if I need to change a test?\u003C\u002Fsummary>\u003Cdiv class=\"a\">\n          \u003Cp>Test limits and settings can be changed per fixture, in configuration files or remotely\n            from a browser, without touching the test sequence.\u003C\u002Fp>\n        \u003C\u002Fdiv>\u003C\u002Fdetails>\n        \u003Cdetails>\u003Csummary>What are the frame's dimensions?\u003C\u002Fsummary>\u003Cdiv class=\"a\">\n          \u003Cp>Closed, Frame 01 Gen 2 (BT201) measures 300 × 270 × 254 mm and weighs 5.4 kg. The\n            available DUT area is 230 × 140 × 35 mm, with a 290 × 260 × 63.5 mm mounting area for\n            boards underneath. Full dimensions are in the BT201 datasheet.\u003C\u002Fp>\n        \u003C\u002Fdiv>\u003C\u002Fdetails>\n        \u003Cdetails>\u003Csummary>Are there per-seat software license fees?\u003C\u002Fsummary>\u003Cdiv class=\"a\">\n          \u003Cp>No. eLink has no per-seat programming license fees. The software is licensed per\n            fixture under the eLink software license agreement. We keep ownership of the eLink\n            platform, framework, and standard modules, and ownership of work written for your\n            program follows your statement of work.\u003C\u002Fp>\n        \u003C\u002Fdiv>\u003C\u002Fdetails>\n        \u003Cdetails>\u003Csummary>Which test instruments are supported?\u003C\u002Fsummary>\u003Cdiv class=\"a\">\n          \u003Cp>The driver library includes the Rigol DS1054Z oscilloscope, Siglent SDM3055 and SDM3045\n            bench multimeters, the B&amp;K Precision 1900B programmable supply, addressable LED\n            indicators, and UART connections for DUT command shells and JSON-RPC firmware. Other\n            instruments are integrated as part of the design package.\u003C\u002Fp>\n        \u003C\u002Fdiv>\u003C\u002Fdetails>\n        \u003Cdetails>\u003Csummary>What else can you help with?\u003C\u002Fsummary>\u003Cdiv class=\"a\">\n          \u003Cp>Around the fixture itself, we develop DUT test firmware on Zephyr RTOS, write drivers\n            for accessories and new interfaces, build APIs to connect fixtures to your other tools,\n            assess designs for manufacturability and testability, and support reshoring.\u003C\u002Fp>\n        \u003C\u002Fdiv>\u003C\u002Fdetails>\n      \u003C\u002Fdiv>\n    \u003C\u002Fdiv>\n  \u003C\u002Fsection>\n\n  \n  \u003Csection class=\"hm-section\">\n    \u003Cdiv class=\"hm-wrap\">\n      \u003Cdiv class=\"fx-faq-head\">\n        \u003Ch2 class=\"hm-h2\" style=\"margin:0\">Frame 01 Gen 2 gallery\u003C\u002Fh2>\n        \u003Ca class=\"hm-btn hm-btn--ghost\" href=\"\u002Ffiles\u002Felink-fixtures\u002FD-BT201-SP.pdf\">Download the\n          BT201 frame datasheet (PDF)\u003C\u002Fa>\n      \u003C\u002Fdiv>\n      \u003Cdiv class=\"fx-gal\">\n        \u003Cfigure>\u003Cimg src=\"\u002Fimages\u002Felink-fixtures\u002Fframe-01-gen-2-closed-over-dut.webp\"\n          alt=\"Frame 01 Gen 2 closed over a DUT, with the press handle raised.\">\u003C\u002Ffigure>\n        \u003Cfigure>\u003Cimg src=\"\u002Fimages\u002Felink-fixtures\u002Fframe-01-gen-2-open-ribbon-cables-600.webp\"\n          srcset=\"\u002Fimages\u002Felink-fixtures\u002Fframe-01-gen-2-open-ribbon-cables-600.webp 600w, \u002Fimages\u002Felink-fixtures\u002Fframe-01-gen-2-open-ribbon-cables.webp 1200w\"\n          sizes=\"(max-width: 760px) 45vw, 300px\" loading=\"lazy\"\n          alt=\"Frame 01 Gen 2 open, showing the ribbon cables and the control board inside.\">\u003C\u002Ffigure>\n        \u003Cfigure>\u003Cimg src=\"\u002Fimages\u002Felink-fixtures\u002Fframe-01-gen-2-side-closed-600.webp\"\n          srcset=\"\u002Fimages\u002Felink-fixtures\u002Fframe-01-gen-2-side-closed-600.webp 600w, \u002Fimages\u002Felink-fixtures\u002Fframe-01-gen-2-side-closed.webp 1200w\"\n          sizes=\"(max-width: 760px) 45vw, 300px\" loading=\"lazy\"\n          alt=\"Frame 01 Gen 2 closed, side view.\">\u003C\u002Ffigure>\n        \u003Cfigure>\u003Cimg src=\"\u002Fimages\u002Felink-fixtures\u002Fframe-01-gen-2-side-open-600.webp\"\n          srcset=\"\u002Fimages\u002Felink-fixtures\u002Fframe-01-gen-2-side-open-600.webp 600w, \u002Fimages\u002Felink-fixtures\u002Fframe-01-gen-2-side-open.webp 1200w\"\n          sizes=\"(max-width: 760px) 45vw, 300px\" loading=\"lazy\"\n          alt=\"Frame 01 Gen 2 open, side view.\">\u003C\u002Ffigure>\n        \u003Cfigure>\u003Cimg src=\"\u002Fimages\u002Felink-fixtures\u002Fsignal-fanout-board-600.webp\"\n          srcset=\"\u002Fimages\u002Felink-fixtures\u002Fsignal-fanout-board-600.webp 600w, \u002Fimages\u002Felink-fixtures\u002Fsignal-fanout-board.webp 1000w\"\n          sizes=\"(max-width: 760px) 45vw, 300px\" loading=\"lazy\"\n          alt=\"A signal fanout board for the frame.\">\u003C\u002Ffigure>\n      \u003C\u002Fdiv>\n    \u003C\u002Fdiv>\n  \u003C\u002Fsection>\n\n  \n  \u003Csection class=\"hm-section hm-section--dark tx-team-lt\">\n    \u003Cdiv class=\"hm-wrap fx-close\">\n      \u003Cdiv>\n        \u003Ch2 class=\"hm-h2\">Start a fixture program\u003C\u002Fh2>\n        \u003Cp class=\"hm-lede\">Tell us about your DUT, what it needs to be tested for, and your\n          timeline. We will put together a plan and a quote.\u003C\u002Fp>\n        \u003Cp style=\"margin-top:24px\">\u003Ca class=\"hm-btn hm-btn--primary\"\n          href=\"\u002Fconnect?looking_for=eLink%E2%84%A2%20test%20fixture\">Talk with a fixture\n          engineer\u003C\u002Fa>\u003C\u002Fp>\n      \u003C\u002Fdiv>\n      \u003Cdiv class=\"fx-buy\">\n        \u003Cimg src=\"\u002Fimages\u002Felink-fixtures\u002Fbase-frame-bt201-f50-00a.webp\"\n          alt=\"Base fixture frame BT201-F50-00A, open, with a blank pogo plate.\">\n        \u003Cdiv>\n          \u003Ch3>Base fixture frame: \u003Cspan style=\"white-space:nowrap\">BT201-F50-00A\u003C\u002Fspan>\u003C\u002Fh3>\n          \u003Cp>Base open frame with a blank pogo plate and acrylic top. Typically ships within 1\n            business day.\u003C\u002Fp>\n          \u003Cdiv class=\"hm-btns\">\n            \u003Ca class=\"fx-digikey\"\n              href=\"https:\u002F\u002Fwww.digikey.com\u002Fen\u002Fsupplier-centers\u002Fboulder-engineering-studio?utm_source=5469&amp;utm_medium=supplier&amp;utm_campaign=disti\"\n              target=\"_blank\" rel=\"noopener\">\u003Cimg\n              src=\"\u002Fimages\u002Felink-fixtures\u002Fbuy-now-at-digikey.webp\" alt=\"Buy now at DigiKey\"\n              width=\"160\" height=\"112\">\u003C\u002Fa>\n            \u003Ca class=\"hm-btn hm-btn--ghost\"\n              href=\"\u002Fconnect?looking_for=eLink%E2%84%A2%20test%20fixture&amp;tell_us_a_bit_about_what_you_are_looking_for_=I%27d%20like%20to%20buy%20the%20BT201-F50-00A%20base%20fixture%20frame%20direct.\">Request\n              to buy direct\u003C\u002Fa>\n          \u003C\u002Fdiv>\n        \u003C\u002Fdiv>\n      \u003C\u002Fdiv>\n    \u003C\u002Fdiv>\n  \u003C\u002Fsection>\n\u003C\u002Fdiv>",1795194793172]